Home

Results 21 - 30 of 937,872 for activities package. Search took 7.761 seconds.  
Sort by date/Sort by relevance
-- Module IN-CS3-operationcodes (Q.1238.1:06/2000) IN-CS3-operationcodes {itu-t recommendation q 1238 modules(1) in-cs3-operationcodes(3) version1(0)} DEFINITIONS ::= BEGIN IMPORTS ros-InformationObjects FROM IN-CS3-object-identifiers {itu-t recommendation q 1238 modules(1) in-cs3-object-identifiers(0) version1(0)} Code FROM Remote-Operations-Information-Objects {joint-iso-itu-t remote-operations(4) informationObjects(5) version1(0)}; -- the operations are grouped by the identified operation packages. -- SCF activation Package opcode-initialDP Code ::= local:0 -- Basic BCP DP Package opcode-originationAttemptAuthorized Code ::= local:1 opcode-collectedInformation Code ::= local:2 opcode-analysedInformation Code ::= local:3 opcode-routeSelectFailure Code ::= local:4 opcode-oCalledPartyBusy Code ::= local:5 opcode-oNoAnswer Code ::= local:6 opcode-oAnswer Code ::= local:7 opcode-oDisconnect Code ::= local:8 opcode-termAttemptAuthorized Code ::= local:9 opcode-tBusy Code ::= local:10 opcode-tNoAnswer Code ::= local:11 opcode-tAnswer Code ::= local:12 opcode-tDisconnect Code ::= local:13 opcode-facilitySelectedAndAvailable Code ::= local:80 opcode-originationAttempt Code ::= local:81 opcode-terminationAttempt Code ::= local:82 opcode-oAbandon Code ::= local:83 -- Advanced BCP DP Package opcode-oMidCall Code ::= local:14 opcode-tMidCall Code ::= local:15 opcode-oSuspended Code ::= local:84 opcode-tSuspended Code ::= local:85 -- SCF/SRF activation of assist Package opcode-assistRequestInstructions Code ::= local:16 -- Assist connection establishment Package opcode-establishTemporaryConnection Code ::= local:17 -- Generic disconnect resource Package opcode-disconnectForwardConnection Code ::= local:18 opcode-dFCWithArgument Code ::= local:86 -- Non-assisted connection establishment Package -- establishment ASE; opcode-connectToResource Code ::= local:19 -- Connect Package (elementary SSF function) opcode-connect Code ::= local:20 -- Call handling Package (elementary SSF function) opcode-holdCallInNetwork Code ::= local:21 opcode-releaseCall Code ::= local:22 -- BCSM Event handling Package opcode-requestReportBCSMEvent Code ::= local:23 opcode-eventReportBCSM Code ::= local:24 -- Charging Event handling Package opcode-requestNotificationChargingEvent Code ::= local:25 opcode-eventNotificationCharging Code ::= local:26 -- SSF call processing Package opcode-collectInformation Code ::= local:27 opcode-analyseInformation Code ::= local:28 opcode-selectRoute Code ::= local:29 opcode-selectFacility Code ::= local:30 opcode-continue Code ::= local:31 opcode-authorizeTermination Code ::= local:87 -- SCF call initiation Package opcode-initiateCallAttempt Code ::= local:32 -- Timer Package opcode-resetTimer Code ::= local:33 -- Billing Package opcode-furnishChargingInformation Code ::= local:34 -- Charging Package opcode-applyCharging Code ::= local:35 opcode-applyChargingReport Code ::= local:36 -- Status reporting Package opcode-requestCurrentStatusReport Code ::= local:37 opcode-requestEveryStatusChangeReport Code ::= local:38 opcode-requestFirstStatusMatchReport Code ::= local:39 opcode-statusReport Code ::= local:40 -- Traffic management Package opcode-callGap Code ::= local:41 -- Service management Package opcode-activateServiceFiltering Code ::= local:42 opcode-serviceFilteringResponse Code ::= local:43 -- Call report Package opcode-callInformationReport Code ::= local:44 opcode-callInformationRequest Code ::= local:45 -- Signalling control Package opcode-sendChargingInformation Code ::= local:46 -- Specialized resource control Package opcode-playAnnouncement Code ::= local:47 opcode-promptAndCollectUserInformation Code ::= local:48 opcode-specializedResourceReport Code ::= local:49 -- Cancel Package opcode-cancel Code ::= local:53 opcode-cancelStatusReportRequest Code ::= local:54 -- Activity Test Package opcode-activityTest Code ::= local:55 -- CPH Response Package opcode-continueWithArgument Code ::= local:88 opcode-createCallSegmentAssociation Code ::= local:89 opcode-disconnectLeg Code ::= local:90 opcode-mergeCallSegments Code ::= local:91 opcode-moveCallSegments Code ::= local:92 opcode-moveLeg Code ::= local:93 opcode-reconnect Code ::= local:94 opcode-splitLeg Code ::= local:95 -- Exception Inform Package opcode-entityReleased Code ::= local:96 -- Trigger Management Package opcode-manageTriggerData Code ::= local:97 opcode-createOrRemoveTriggerData Code ::= local:135 -- Trigger Call Management Package opcode-setServiceProfile Code ::= local:136 -- USI Handling Package opcode-requestReportUTSI Code ::= local:98 opcode-sendSTUI Code ::= local:100 opcode-reportUTSI Code ::= local:101 -- Facility IE Handling Package opcode-sendFacilityInformation Code ::= local:102 opcode-requestReportFacilityEvent Code ::= local:103 opcode-eventReportFacility Code ::= local:104 -- SRF/SCF interface opcode-promptAndReceiveMessage Code ::= local:107 opcode-scriptInformation Code ::= local:108 opcode-scriptEvent Code ::= local:109 opcode-scriptRun Code ::= local:110 opcode-scriptClose Code ::= local:111 opcode-srfCallGap Code ::= local:139 -- SCF/SCF interface opcode-establishChargingRecord Code ::= local:112 opcode-handlingInformationRequest Code ::= local:113 opcode-handlingInformationResult Code ::= local:114 opcode-networkCapability Code ::= local:115 opcode-notificationProvided Code ::= local:116 opcode-confirmedNotificationProvided Code ::= local:117 opcode-provideUserInformation Code ::= local:118 opcode-confirmedReportChargingInformation Code ::= local:119 opcode-reportChargingInformation Code ::= local:120 opcode-requestNotification Code ::= local:121 opcode-runUserScript Code ::= local:140 opcode-transferSTSI Code ::= local:141 -- SCF/SDF interface opcode-execute Code ::= local:10 opcode-trafficFlowControl Code ::= local:138 -- CUSF/SCF interface opcode-activationReceivedAndAuthorized Code ::= local:122 opcode-initiateAssociation Code ::= local:123 opcode-associationReleaseRequested Code ::= local:124 opcode-componentReceived Code ::= local:125 opcode-releaseAssociation Code ::= local:126 opcode-requestReportBCUSMEvent Code ::= local:127 opcode-sendComponent Code ::= local:130 opcode-connectAssociation Code ::= local:132 opcode-continueAssociation Code ::= local:133 opcode-eventReportBCUSM Code ::= local:134 opcode-initialAssociationDP Code ::= local:131 END -- Generated by Asnp, the ASN.1 pretty-printer of France Telecom R&D
Language:English
Score: 960885.3 - https://www.itu.int/wftp3/Publ...2000/IN-CS3-operationcodes.asn
Data Source: un
IN-CS3-operationcodes (Q.1238.1:06/2000) -- Module IN-CS3-operationcodes (Q.1238.1:06/2000) -- See also ITU-T Q.1238.1 (06/2000) -- See also the index of all ASN.1 assignments needed in this document IN-CS3-operationcodes {itu-t recommendation q 1238 modules(1) in-cs3-operationcodes(3) version1(0)} DEFINITIONS ::= BEGIN IMPORTS ros-InformationObjects FROM IN-CS3-object-identifiers {itu-t recommendation q 1238 modules(1) in-cs3-object-identifiers(0) version1(0)} Code FROM Remote-Operations-Information-Objects {joint-iso-itu-t remote-operations(4) informationObjects(5) version1(0)}; -- the operations are grouped by the identified operation packages. -- SCF activation Package opcode-initialDP Code ::= local:0 -- Basic BCP DP Package opcode-originationAttemptAuthorized Code ::= local:1 opcode-collectedInformation Code ::= local:2 opcode-analysedInformation Code ::= local:3 opcode-routeSelectFailure Code ::= local:4 opcode-oCalledPartyBusy Code ::= local:5 opcode-oNoAnswer Code ::= local:6 opcode-oAnswer Code ::= local:7 opcode-oDisconnect Code ::= local:8 opcode-termAttemptAuthorized Code ::= local:9 opcode-tBusy Code ::= local:10 opcode-tNoAnswer Code ::= local:11 opcode-tAnswer Code ::= local:12 opcode-tDisconnect Code ::= local:13 opcode-facilitySelectedAndAvailable Code ::= local:80 opcode-originationAttempt Code ::= local:81 opcode-terminationAttempt Code ::= local:82 opcode-oAbandon Code ::= local:83 -- Advanced BCP DP Package opcode-oMidCall Code ::= local:14 opcode-tMidCall Code ::= local:15 opcode-oSuspended Code ::= local:84 opcode-tSuspended Code ::= local:85 -- SCF/SRF activation of assist Package opcode-assistRequestInstructions Code ::= local:16 -- Assist connection establishment Package opcode-establishTemporaryConnection Code ::= local:17 -- Generic disconnect resource Package opcode-disconnectForwardConnection Code ::= local:18 opcode-dFCWithArgument Code ::= local:86 -- Non-assisted connection establishment Package -- establishment ASE; opcode-connectToResource Code ::= local:19 -- Connect Package (elementary SSF function) opcode-connect Code ::= local:20 -- Call handling Package (elementary SSF function) opcode-holdCallInNetwork Code ::= local:21 opcode-releaseCall Code ::= local:22 -- BCSM Event handling Package opcode-requestReportBCSMEvent Code ::= local:23 opcode-eventReportBCSM Code ::= local:24 -- Charging Event handling Package opcode-requestNotificationChargingEvent Code ::= local:25 opcode-eventNotificationCharging Code ::= local:26 -- SSF call processing Package opcode-collectInformation Code ::= local:27 opcode-analyseInformation Code ::= local:28 opcode-selectRoute Code ::= local:29 opcode-selectFacility Code ::= local:30 opcode-continue Code ::= local:31 opcode-authorizeTermination Code ::= local:87 -- SCF call initiation Package opcode-initiateCallAttempt Code ::= local:32 -- Timer Package opcode-resetTimer Code ::= local:33 -- Billing Package opcode-furnishChargingInformation Code ::= local:34 -- Charging Package opcode-applyCharging Code ::= local:35 opcode-applyChargingReport Code ::= local:36 -- Status reporting Package opcode-requestCurrentStatusReport Code ::= local:37 opcode-requestEveryStatusChangeReport Code ::= local:38 opcode-requestFirstStatusMatchReport Code ::= local:39 opcode-statusReport Code ::= local:40 -- Traffic management Package opcode-callGap Code ::= local:41 -- Service management Package opcode-activateServiceFiltering Code ::= local:42 opcode-serviceFilteringResponse Code ::= local:43 -- Call report Package opcode-callInformationReport Code ::= local:44 opcode-callInformationRequest Code ::= local:45 -- Signalling control Package opcode-sendChargingInformation Code ::= local:46 -- Specialized resource control Package opcode-playAnnouncement Code ::= local:47 opcode-promptAndCollectUserInformation Code ::= local:48 opcode-specializedResourceReport Code ::= local:49 -- Cancel Package opcode-cancel Code ::= local:53 opcode-cancelStatusReportRequest Code ::= local:54 -- Activity Test Package opcode-activityTest Code ::= local:55 -- CPH Response Package opcode-continueWithArgument Code ::= local:88 opcode-createCallSegmentAssociation Code ::= local:89 opcode-disconnectLeg Code ::= local:90 opcode-mergeCallSegments Code ::= local:91 opcode-moveCallSegments Code ::= local:92 opcode-moveLeg Code ::= local:93 opcode-reconnect Code ::= local:94 opcode-splitLeg Code ::= local:95 -- Exception Inform Package opcode-entityReleased Code ::= local:96 -- Trigger Management Package opcode-manageTriggerData Code ::= local:97 opcode-createOrRemoveTriggerData Code ::= local:135 -- Trigger Call Management Package opcode-setServiceProfile Code ::= local:136 -- USI Handling Package opcode-requestReportUTSI Code ::= local:98 opcode-sendSTUI Code ::= local:100 opcode-reportUTSI Code ::= local:101 -- Facility IE Handling Package opcode-sendFacilityInformation Code ::= local:102 opcode-requestReportFacilityEvent Code ::= local:103 opcode-eventReportFacility Code ::= local:104 -- SRF/SCF interface opcode-promptAndReceiveMessage Code ::= local:107 opcode-scriptInformation Code ::= local:108 opcode-scriptEvent Code ::= local:109 opcode-scriptRun Code ::= local:110 opcode-scriptClose Code ::= local:111 opcode-srfCallGap Code ::= local:139 -- SCF/SCF interface opcode-establishChargingRecord Code ::= local:112 opcode-handlingInformationRequest Code ::= local:113 opcode-handlingInformationResult Code ::= local:114 opcode-networkCapability Code ::= local:115 opcode-notificationProvided Code ::= local:116 opcode-confirmedNotificationProvided Code ::= local:117 opcode-provideUserInformation Code ::= local:118 opcode-confirmedReportChargingInformation Code ::= local:119 opcode-reportChargingInformation Code ::= local:120 opcode-requestNotification Code ::= local:121 opcode-runUserScript Code ::= local:140 opcode-transferSTSI Code ::= local:141 -- SCF/SDF interface opcode-execute Code ::= local:10 opcode-trafficFlowControl Code ::= local:138 -- CUSF/SCF interface opcode-activationReceivedAndAuthorized Code ::= local:122 opcode-initiateAssociation Code ::= local:123 opcode-associationReleaseRequested Code ::= local:124 opcode-componentReceived Code ::= local:125 opcode-releaseAssociation Code ::= local:126 opcode-requestReportBCUSMEvent Code ::= local:127 opcode-sendComponent Code ::= local:130 opcode-connectAssociation Code ::= local:132 opcode-continueAssociation Code ::= local:133 opcode-eventReportBCUSM Code ::= local:134 opcode-initialAssociationDP Code ::= local:131 END -- Generated by Asnp, the ASN.1 pretty-printer of France Telecom R&D
Language:English
Score: 960885.3 - https://www.itu.int/wftp3/Publ...000/IN-CS3-operationcodes.html
Data Source: un
II.2 Additional requirements — The equipment must be secured against movement within the outer packaging and must be equipped with an effective means of preventing accidental activation. — The number of cells or batteries in each package must not exceed the appropriate number for the equipment’s operation, plus two spares. — Each package of cells or batteries, or the completed package, must be capable of withstanding a 1.2 m drop test in any orientation without: — damage to cells or batteries contained therein; — shifting of the contents so as to allow battery to battery (or cell to cell) contact; — release of contents. — Each package must be marked with the appropriate lithium battery mark (Figure 5-3), in accordance with Part 5;2.4.16. . . . (...) II.2 Additional requirements — The equipment must be secured against movement within the outer packaging and must be equipped with an effective means of preventing accidental activation. — Cells and batteries must be protected so as to prevent short circuits. — The equipment must be packed in strong rigid outer packagings constructed of suitable material of adequate strength and design in relation to the packaging’s capacity and its intended use unless the battery is afforded equivalent protection by the equipment in which it is contained. — Each package must be marked with the appropriate lithium battery mark (Figure 5-3), in accordance with Part 5;2.4.16. (...) II.2 Additional requirements — The equipment must be secured against movement within the outer packaging and must be equipped with an effective means of preventing accidental activation. — Cells and batteries must be protected so as to prevent short circuits. — The equipment must be packed in strong rigid outer packagings constructed of suitable material of adequate strength and design in relation to the packaging’s capacity and its intended use unless the battery is afforded equivalent protection by the equipment in which it is contained. — Each package must be marked with the appropriate lithium battery mark (Figure 5-3), in accordance with Part 5;2.4.16.
Language:English
Score: 956405.1 - https://www.icao.int/safety/Da.../WG16/DGPWG.16.WP.045.2.en.pdf
Data Source: un
The shipper is not required to await an acknowledgement from the competent authority, nor is the competent authority required to make such acknowledgement of receipt of the certificate; b) For each of the following types of shipments: i) Type C packages containing radioactive material with an activity greater than 3000 A1 or 3000 A2, as appropriate, or 1000 TBq, whichever is the lower; ii) Type B(U) packages containing radioactive material with an activity greater than 3000 A1 or 3000 A2, as appropriate, or 1000 TBq, whichever is the lower; iii) Type B(M) packages; iv) Shipment under special arrangement; DGP-WG/19-WP/15 - 3 - UN Model Regulations, 5.1.5.1.4 (b) (see ST/SG/AC.10/46/Add.1) the shipper must notify the competent authority of the country of origin of the shipment and the competent authority of each country through or into which the consignment is to be transported. (...) U-dep., solid, metal oxide) in which case the indicated radionuclide may differ from the radionuclide(s) authorized in the package design certificate. c) The maximum activity of the radioactive contents during transport expressed in units of becquerels (Bq) with an appropriate SI prefix symbol (see 1;3.2). For fissile material, the mass of fissile material (or mass of each fissile nuclide for mixtures when appropriate) in units of grams (g), or appropriate multiples thereof, may be used in place of activity; d) The category of the package, overpack or freight container, as assigned per 1.2.3.1.4, i.e.
Language:English
Score: 955672.3 - https://www.icao.int/safety/Da.../WG19/DGPWG.19.WP.015.1.en.pdf
Data Source: un
 Page 112 - Cloud computing: From paradigm to operation           Basic HTML Version Table of Contents View Full Version Page 112 - Cloud computing: From paradigm to operation P. 112 1 Framework and requirements for cloud computing Figure A.5 – Provider–peer provider relationship for use service activity A.3 The cloud service developer–cloud service provider relationship Cloud service developers create and package service implementations and hand them to cloud service providers for deployment and operation. Therefore, the cloud service developer interacts with the cloud service provider to: 1) inspect the cloud service provider's environment for service execution; 2) test service implementations; 3) hand over service implementation packages. The development support functional components support the cloud computing activities of the cloud service developer, including the develop service, test service and maintain service cloud computing activities. (...) The lines in radiating from the developer environment component in Figure A.7 show that the cloud service developer develops the implementation of a cloud service and composes the service using the development environment functional component and then uses the build management system to build the service and its related artefacts into a deployable package. The arrows to/from the test management functional component indicate that the test management system performs appropriate testing against the built package, fetching the package from the build management system and interacting with the provider's environment via the development access functional component to deploy a test version of the service and execute the tests. 104     107     108     109     110     111     112     113     114     115     116     117          
Language:English
Score: 955221.3 - https://www.itu.int/en/publica.../files/basic-html/page112.html
Data Source: un
WHO is also currently developing simplified and appropriate training packages that correspond to these guidelines. Training packages will be standardized to WHO’s clinical and operational recommendations and focus on essential core competencies. (...) Development of WHO core training packages for in-service personnel. The development process will focus on training packages for the key competencies involved in chronic HIV/AIDS care and antiretroviral therapy at first- and second-level facilities. (...) WHO will work with countries and institutions to certify trainees who have successfully participated in training activities based on the WHO training packages (see the objective on establishing incountry certification of HIV/AIDS competence).
Language:English
Score: 954248 - https://www.who.int/3by5/publi...pacity_building/en/index1.html
Data Source: un
WHO is also currently developing simplified and appropriate training packages that correspond to these guidelines. Training packages will be standardized to WHO’s clinical and operational recommendations and focus on essential core competencies. (...) Development of WHO core training packages for in-service personnel. The development process will focus on training packages for the key competencies involved in chronic HIV/AIDS care and antiretroviral therapy at first- and second-level facilities. (...) WHO will work with countries and institutions to certify trainees who have successfully participated in training activities based on the WHO training packages (see the objective on establishing incountry certification of HIV/AIDS competence).
Language:English
Score: 954248 - https://www.who.int/3by5/publi...pacity_building/en/index1.html
Data Source: un
Women will share experiences, gain self-confidence in their abilities and enhance their status in the family and in the community, becoming less susceptible to be radicalized. ACTIVITY PACKAGE 1 ACTIVITY PACKAGE 2 © Hedayah ACTIVITY PACKAGES 1-4 ACTIVITY PACKAGE 3 ACTIVITY PACKAGE 4 Creation of 2 Resources Centers based on Mutakallim offices premises - events and activities aimed at the awareness and prevention of VE among women and youth. Training of 20 women-leader on the risks of radicalization and VE, means of prevention, mechanisms of identification and response to early signs of radicalization. Income generating activities will be implemented for 30 women selected as the most vulnerable. (...) The ability of youth audiences to recognize and critically assess online extremist content and propaganda will be strengthened. ACTIVITY PACKAGE 1 ACTIVITY PACKAGE 2 © Hedayah ACTIVITY PACKAGES 1-2 After a skills gaps assessment of digital and media literacy competencies among youth (14-18 and 18-28), development of a digital and media literacy module on essential life skills.
Language:English
Score: 951894.6 - https://www.un.org/securitycou...entral-asia_un-ctc-meeting.pdf
Data Source: un
Such articles and packages must be assigned to Compatibility Groups D or E. (...) Shipments under this exception must be under exclusive use. 7.2.4 Classification of packages 7.2.4.1 The quantity of radioactive material in a package must not exceed the relevant limits for the package type as specified below. 7.2.4.1.1 Classification as excepted packages 7.2.4.1.1.1 Packages may be classified as excepted packages if: a) they are empty packagings having contained radioactive material; b) they contain instruments or articles in limited quantities as specified in Table 2-15; c) they contain articles manufactured of natural uranium, depleted uranium or natural thorium; or d) they contain radioactive material in limited quantities as specified in Table 2-15. 7.2.4.1.1.2 A package containing radioactive material may be classified as an excepted package provided that the radiation level at any point on its external surface does not exceed 5 μSv/h. 7.2.4.1.1.3 Radioactive material which is enclosed in or is included as a component part of an instrument or other manufactured article may be classified under UN 2911 — Radioactive material, excepted package — instruments or articles, provided that only if: a) the radiation level at 10 cm from any point on the external surface of any unpackaged instrument or article is not greater than 0.1 mSv/h; and b) each instrument or article bears the marking “RADIOACTIVE” except: i) radioluminescent time-pieces or devices; ii) consumer products that either have received regulatory approval according to 1;6.1.4 b) or do not individually exceed the activity limit for an exempt consignment in Table 2-12 (column 5), provided such products are transported in a package that bears the marking “RADIOACTIVE” on an internal surface in such a manner that warning of the presence of radioactive material is visible on opening the package; c) the active material is completely enclosed by non-active components (a device performing the sole function of containing radioactive material must not be considered to be an instrument or manufactured article); and d) the limits specified in columns 2 and 3 of Table 2-15 are met for each individual item and each package, respectively. 7.2.4.1.1.4 Radioactive material with an activity in forms other than as specified in 7.2.4.1.1.3 and with an activity not exceeding the limits specified in column 4 of Table 2-15 may be classified under UN 2910 — Radioactive material, excepted package — limited quantity of material, provided that: a) the package retains its radioactive contents under routine conditions of transport; and b) the package bears the marking “RADIOACTIVE” on an internal surface in such a manner that a warning of the presence of radioactive material is visible on opening the package. (...) Table 2-15. Activity limits for excepted packages Instruments or article Materials Physical state of contents Item limits* Package limits* Package limits* Solids Special form 10–2 A1 A1 10–3 A1 Other form 10–2 A2 A2 10–3 A2 Liquids 10–3 A2 10–1 A2 10–4 A2 Gases Tritium 2 × 10–2 A2 2 × 10–1 A2 2 × 10–2 A2 Special form 10–3 A1 10–2 A1 10–3 A1 Other forms 10–3 A2 10–2 A2 10–3 A2 * For mixtures of radionuclides, see 7.2.2.4 to 7.2.2.6. 7.2.4.2 Classification as low specific activity (LSA) material 7.2.4.2.1 Radioactive material may only be classified as LSA material if the definition of LSA in 7.1.3 and the conditions of 7.2.3.1 and, 4;9.2.1 and 7;2.9.2 are met. 7.2.4.3 Classification as surface contaminated object (SCO) 7.2.4.3.1 Radioactive material may be classified as SCO if the definition of SCO in 7.1.3 and the conditions of 7.2.3.2.1 and, 4;9.2.1 and 7;2.9.2 are met. . . .
Language:English
Score: 951412.6 - https://www.icao.int/safety/Da...%2009/DGPWG.09.WP.005.2.en.pdf
Data Source: un
Paragraph 3.1.2.5 of the DGP-WG/21 report: Chapter 1 CLASS 1 — EXPLOSIVES . . . 1.4 COMPATIBILITY GROUPS . . . 1.4.2.1 Certain Division 1.4S explosives, identified by Special Provision A165 in Table 3-1, are subject to Test Series 6 (d) of Part I of the UN UN Manual of Tests and Criteria (see ST/SG/AC.10/11/Rev.6 and Amend.1) to demonstrate that any hazardous effects arising from functioning are confined within the package. Evidence of a hazardous effect outside the package includes: a) denting or perforation of the witness plate beneath the package; b) a flash or flame capable of igniting such as a sheet of 80 ± 3 g/m² paper at a distance of 25 cm from the package; c) disruption of the package causing projection of the explosives contents; or d) a projection which passes completely through the packaging (a projection or fragment retained or stuck in the wall of the packaging is considered as non-hazardous). (...) The water must have an initial pH of 6-8 and a maximum conductivity of 1 mS/m at 20°C. The total activity of the free volume of water must be measured following the 7-day immersion of the test sample. 7.2.3.4.3.4 Demonstration of compliance with the performance standards in 7.2.3.4.1 and, 7.2.3.4.2 and 7.2.3.4.3 must be in accordance with 6;7.11.1 and 6;7.11.2. . . . 7.2.4.1.1.3 Radioactive material which is enclosed in or is included as a component part of an instrument or other manufactured article may be classified under UN 2911 — Radioactive material, excepted package — instruments or articles provided that: a) the dose rate at 10 cm from any point on the external surface of any unpackaged instrument or article is not greater than 0.1 mSv/h; and b) each instrument or article bears the mark “RADIOACTIVE” on its external surface except for the following: i) radioluminescent time-pieces or devices; ii) consumer products that either have received regulatory approval in accordance with 1;6.1.4 c) or do not individually exceed the activity limit for an exempt consignment in Table 2-12 (column 5), provided such products are transported in a package that bears the mark “RADIOACTIVE” on an internal surface in such a manner that a warning of the presence of radioactive material is visible on opening the package; and iii) other instruments or articles too small to bear the mark “RADIOACTIVE”, provided that they are transported in a package that bears the mark “RADIOACTIVE” on its internal surface in such a manner that a warning of the presence of radioactive material is visible on opening the package; c) the active material is completely enclosed by non-active components (a device performing the sole function of containing radioactive material must not be considered to be an instrument or manufactured article); d) the limits specified in columns 2 and 3 of Table 2-14 are met for each individual item and each package, respectively; e) reserved; and UN Model Regulations, 2.7.2.4.1.3 (f) (see ST/SG/AC.10/1/Rev.21, Vol. I and II Corrigendum 1): f) if the package contains fissile material, one of the provisions of 7.2.3.5.1 a) to f) must apply applies. 7.2.4.1.1.4 Radioactive material in forms other than as specified in 7.2.4.1.1.3 and with an activity not exceeding the limits specified in column 4 of Table 2-14 may be classified under UN 2910 — Radioactive material, excepted package — limited quantity of material, provided that: a) the package retains its radioactive contents under routine conditions of transport; b) the package bears the mark “RADIOACTIVE” on either: i) an internal surface in such a manner that a warning of the presence of radioactive material is visible on opening the package; or ii) the outside of the package, where it is impractical to mark an internal surface; and DGP/28-WP/12 - 7 - UN Model Regulations, 2.7.2.4.1.4 (c) (see ST/SG/AC.10/1/Rev.21, Vol.
Language:English
Score: 950991.8 - https://www.icao.int/safety/Da...s/DGP28/DGP.28.WP.012.1.ar.pdf
Data Source: un