Gulf countries share around 15% of the global market for air conditioning, which presents a special challenge for the phase-out of ozone depleting substances. In addition, in high ambient temperatures, air conditioners do not last or perform as well as they do in cooler countries. This is because of the additional stress on the equipment to bridge the gap between cool indoor and high outdoor air temperatures. Leakage and energy efficiency are both significant problems.
Language:English
Score: 1132412.6
-
https://www.unido.org/our-focu...limate-friendly-ways-cool-down
Data Source: un
SUMMARY OF THE INFORMATION SUBMITTED BY PARTIES ON THEIR IMPLEMENTATION OF PARAGRAPH 9 OF DECISION XIX/6 TO PROMOTE A TRANSITION FROM OZONE-DEPLETING SUBSTANCES THAT MINIMIZES ENVIRONMENTAL IMPACT (DECISION XXV/5, PARAGRAPH 3)
Austria has since 2008 prohibited the import and use of HFCs in new fixed air-conditioners
and freezers, including domestic refrigerators, freezers and mobile air-conditioners, allowing the
continued use of HFCs in refrigeration and cooling appliances for specific circumstances. (...) Under the United States Clean Air Act, any equipment used to recover or recycle HFC-134a
from motor vehicle air-conditioners must meet government standards and be tested by an approved
testing laboratory (Underwriters Laboratories or Intertek).
61. (...) Japan requires that only registered collectors perform the recovery of CFCs, HCFCs and
HFCs from commercial refrigerators and air-conditioners at the time of maintenance and disposal.
Language:English
Score: 1131373.2
-
daccess-ods.un.org/acce...en&DS=UNEP/OZL.PRO.26/9&Lang=E
Data Source: ods
ISSUES FOR DISCUSSION BY AND INFORMATION FOR THE ATTENTION OF THE OPEN ENDED WORKING GROUP OF THE PARTIES TO THE MONTREAL PROTOCOL AT ITS FORTY-THIRD MEETING
As it has done for previous
reports, the task force has restricted the scope of the document mainly to room air conditioners and
self-contained commercial refrigeration equipment.
5. (...) While more than 50 per cent of the globally produced air-conditioning units now use
refrigerants with no ozone-depleting potential, in Article 5 parties locally produced room air
conditioners predominantly use HCFC-22 and remain relatively inefficient. (...) Lower-GWP refrigerants comprise: HFC-32, with a GWP of 675, already introduced in many
countries around the world as an energy-efficient lower-GWP refrigerant; blends involving low-GWP
HFCs, hydrofluoroolefins (HFOs), hydrochlorofluoroolefins (HCFOs) or iodofluorocarbon (IFC), with
GWPs ranging from 100 to 750 and varying degrees of flammability; and hydrocarbons (HCs), with
GWP ranging from 1 to 20, such as HC-290, with use currently limited to small-capacity room air
conditioners and portable or window air conditioners due to its higher flammability.

Language:English
Score: 1127198.9
-
https://daccess-ods.un.org/acc...OZL.PRO.WG.1/43/3/REV.1&Lang=E
Data Source: ods
UPDATED SUMMARY OF THE INFORMATION SUBMITTED BY PARTIES ON THEIR IMPLEMENTATION OF PARAGRAPH 9 OF DECISION XIX/6 TO PROMOTE A TRANSITION FROM OZONE-DEPLETING SUBSTANCES THAT MINIMIZES ENVIRONMENTAL IMPACT (DECISION XXV/5, PARAGRAPH 3)
In Japan, requirements for the recovery and destruction of chlorofluorocarbons (CFCs),
HCFCs and HFCs from commercial refrigerators and air-conditioners are in place through its Act
Concerning the Recovery and Destruction of Fluorocarbons. (...) Since
2009 this rule has applied to all new vehicles that have been type-approved in the past. Since 2011,
mobile air-conditioners designed to use the above-mentioned gases have been completely banned for
new types of vehicles. (...) Austria has since 2008 prohibited the import and use of HFCs in new fixed air-conditioners
and freezers, including domestic refrigerators, freezers and mobile air-conditioners, allowing the
continued use of HFCs in refrigeration and cooling appliances for specific circumstances.
Language:English
Score: 1124929.4
-
daccess-ods.un.org/acce...n&DS=UNEP/OZL.PRO.28/11&Lang=E
Data Source: ods
UPDATED SUMMARY OF THE INFORMATION SUBMITTED BY PARTIES ON THEIR IMPLEMENTATION OF PARAGRAPH 9 OF DECISION XIX/6 TO PROMOTE A TRANSITION FROM OZONE-DEPLETING SUBSTANCES THAT MINIMIZES ENVIRONMENTAL IMPACT (DECISION XXV/5, PARAGRAPH 3)
Austria has since 2008 prohibited the import and use of HFCs in new fixed air-conditioners
and freezers, including domestic refrigerators, freezers and mobile air-conditioners, allowing the
continued use of HFCs in refrigeration and cooling appliances for specific circumstances. (...) Japan requires the recovery and destruction of CFCs, HCFCs and HFCs from commercial
refrigerators and air-conditioners by approved destruction facilities at the time of maintenance and
disposal.
67. (...) Under the United States Clean Air Act, any equipment used to recover or recycle HFC-134a
from motor vehicle air-conditioners must meet government standards and be tested by an approved
testing laboratory (Underwriters Laboratories or Intertek).
71.
Language:English
Score: 1124476.7
-
daccess-ods.un.org/acce...n&DS=UNEP/OZL.PRO.27/11&Lang=E
Data Source: ods
Major appliances except air conditioner are already saturated. Hence, the number of room air conditioners is rapidly increased.
(...) In the beginning, 6 items were included this program. - refrigerators and refrigerator-freezers
- room air conditioners
- incandescent lamps
- fluorescent lamps (T-10 tubular 20W, 40W & circular 32W)
- ballasts for T-10 fluorescent lamps
- passenger cars
K O R E A K O R E A I N S T I T U T E I N S T I T U T E O F O F E N E R G Y E N E R G Y R E S E A R C H R E S E A R C H
• In 1999 &2001, 5 items were added to this regulation: - fluorescent lamps (tubular T-8 32W & circular T-10 40W) and associated ballasts, - screw-based compact fluorescent lamps (self-ballasted CFLs), - clothes washers, and - household gas boilers.
• The followings are considered to be added in the future: - gas water heaters, - dishwashers, - T-5 lamps and associated ballasts, - vending machines, and - refrigerators for Kimchi (it is in Korea only for the vegetable food to storage), etc.
(...) The Program also led to an improvement in average energy
efficiency levels for some of the appliances regulated by
TEPS
Appliance
Type
Refrigerator-freezers
Room air conditioners
Incandescent lamps
Fluorescent lamps
Measurement
unit
1993 Efficiency
(market average)
2000 Efficiency
(market average)
% Improvement
in efficiency
kWh/month/liter
COP
lm/W
lm/W
0.113
2.4
10.0
65.0
0.065
3.7
11.0
90.0
74%
54%
10%
39%
K O R E A K O R E A I N S T I T U T E I N S T I T U T E O F O F E N E R G Y E N E R G Y R E S E A R C H R E S E A R C H
Future of Program in Korea Future of Program in Korea
• The program is being studied - extension of subject products
- a shift in testing protocols from KS to ISO for electric appliances
• we are very considering to make MEPS level highly, but not to make the grading in the future.
Language:English
Score: 1121854.8
-
https://www.un.org/esa/sustdev...ues/energy/op/clasp_leeppt.pdf
Data Source: un
Scope of Supply
4.1 KIT 1 – For Training Centers and large/medium service workshops
i) Flushing Machine CPS Model AFM100 or Equivalent with 2 gallons of flushing agent – 279 kits (1 machine/kit)
Powered by air compressed Power Source: 50 PSIG minimum air pressure Operating Range: 00C to 49 0C Air Pressure Gauge: 0 to 100 PSIG Manual Control Valves: 2 way ball type valve to control air supply to the
unit; 3 way ball type valve to control air purge/Flush circulation; 4 way ball valve to control forward and reverse control
Filtration: 100 mesh cleanable screen Heavy duty power coated sheet metal cabinet with wheels Adaptors: One set of universal clamps with 3/8" SAE Male Fittings High Pressure relief valve 125 PSIG Easy one step hooks up air hose and flush hoses Forward/reverse flush valve to eliminate reconnection of hoses Filter with clear removable bowl for flow and filtration verification Large mouth flush fill tube Storage area for 2 one gallon’s flush containers Including 2 gallons of flushing agent for the flushing machine The flushing agent with the next specifications:
o GWP low or equal 0 o Compatible with almost all refrigerant lubricants o Fast evaporating, bio-degradable and non-corrosive o Formulated to remove all common system contaminants including
refrigerant oils, internal component particles and remnants of leak sealants known to cause damage to systems and service equipment alike.
o The cleaning agent should be suitable for proper operation with the cleaning machine
Instruction manual in Spanish.
ii) Air compressor with hoses and connections for use with the Flushing Machine CPS Model AFM or Equivalent – 279 kits (1 set/kit)
Portable electric air compressor with: o horizontal tank of 2 gallons; o 0.33 H.P.; o Power supply: 120 V / 60 Hz; o Full load amperage 2.6 A; o Automatic shut-off at a pressure of 90PSI o Maximum pressure: 100 PSI
Including hoses and fittings to connect to the Flushing machine Model AFM 100 or equivalent.
Wire wound air hose; color yellow; inner diameter 1/4"; length 12 feet; size 1/4" NPT; maximum pressure 185 PSI
Industrial standard coupler, hose connection (F) NPT, 1/4" NPT size connection; body size 1/4"
Industrial interchange coupler plug; hose connection (F) NPT, 1/4" NPT size connection; body size 1/4"
Instruction manual in Spanish.
3
iii) Flushing Kit for air-conditioners CPS model TLFGRA or Equivalent – 279 kits (1 set/kit)
Refillable Flush cylinder with minimum capacity of 600 ml with shut-off valve
18” A/C Hose Universal adapter and fittings to connect the air compressor and hose of
nitrogen tank One (1) gallon of flushing agent with the following specifications:
o GWP low or equal to zero (0) o Compatible with almost all refrigerant lubricants o Fast evaporating, bio-degradable and non-corrosive o Formulated to remove all common system contaminants including
refrigerant oils, internal component particles and remnants of leak sealants known to cause damage to systems and service equipment alike.
Instruction manual in Spanish.
iv) Portable Nitrogen blowing equipment – 279 kits (1 set/kit) With Nitrogen regulator Pressure scales: output of at least 0-4 bar and input of at least 0-200
bar Input connections: CGA-580 Output connections: 9/16"-18 UNF right Hose: 1/4" SAE and length of at least 3 meters Including cylinder carrying trolley Nitrogen cylinder with capacity of 13.4 liters and valve CGA-580. Gauges: 50-60mm diameter; Instruction manual in Spanish.
v) Universal Connection Kit for air-conditioners Systems Flushing – 279 kits (1 set/kit)
Including, in a resistant case, all necessary parts required to connect any flushing machine to the most common A/C system ports
vi) Multi-Function Digital Manifold –Mastercool Model 99661-EU or Equivalent 279 kits (1 set/kit)
Digital display of: pressure, vacuum, temperature, superheat and subcooling.
Includes, in a transport case: manifold with a set of 3 X 150 cm hoses (yellow, blue and red), vacuum sensor with cable, clamp on thermocouple and 2 ball valve 5/16" SAE hose adaptors for R-410A.
Includes 64 refrigerants Selectable Pressure: PSI, inHg; Bar, Mpa, Kg/cm2. (...) Flexible 16” probe for difficult to reach locations
Flexible 16” probe for difficult to reach locations Display: Progressive LCD with vertical bars corresponding to the
magnitude of the detected leak Visual indication of the selected sensitivity range Tested and approved to work with R1234yf as well as R32 and R410a Sensor Life: 2000 hours Operating Temperature Range: 0 to 140˚F Power: Two (2) D Batteries Battery Life: 60 hours continuous use “Super Sensitive Function” allows the unit further sensitizing beyond the
standard settings for locating small leaks with gases such as R1234yf and R407C
Instruction manual in Spanish.
xvi) Tube cutter – 279 kits (1 tube cutter/kit) Tube cutter for cupper tubes OD 4-28 mm (1/8" - 1-1/8")
6
4.2 – KIT 2 – For small workshops and independent technicians
The components of each kit must be packed and sent in a single package.
i) Flushing Kit for air-conditioners CPS model TLFGRA or Equivalent – 360 kits (1 set/kit)
Refillable Flush cylinder with minimum capacity of 600 ml with shut-off valve
18” A/C Hose Universal adapter and fittings to connect the air compressor and hose of
nitrogen tank One (1) gallon of flushing agent with the following specifications:
o GWP low or equal to zero (0) o Compatible with almost all refrigerant lubricants o Fast evaporating, bio-degradable and non-corrosive o Formulated to remove all common system contaminants including
refrigerant oils, internal component particles and remnants of leak sealants known to cause damage to systems and service equipment alike.
Instruction manual in Spanish.
ii) Nitrogen Blowing Equipment with trolley for the cylinder – 360 kits (1 set/kit)
With Nitrogen regulator Pressure scales: output of at least 0-4 bar and input of at least 0-200
bar Input connections: CGA-580 Output connections: 9/16"-18 UNF right Hose: 1/4" SAE and length of at least 3 meters Including cylinder carrying trolley Nitrogen cylinder with capacity of 13.4 liters and valve CGA-580. Gauges: 50-60mm diameter; Instruction manual in Spanish
iii) Universal Connection Kit for air-conditioners Systems Flushing – 360 kits (1 set/kit)
Including, in a resistant case, all necessary parts required to connect any flushing machine to the most common A/C system ports
iv) Multi-Function Digital manifold Mastercool Model 99661-EU or
Equivalent – 360 kits (1 set/kit) Digital display of: pressure, vacuum, temperature, superheat and
subcooling. Includes, in a transport case: manifold with a set of 3 X 150 cm hoses
(yellow, blue and red), vacuum sensor with cable, clamp on thermocouple and 2 ball valve 5/16" SAE hose adaptors for R-410A.
Includes 64 refrigerants Selectable Pressure: PSI, inHg; Bar, Mpa, Kg/cm2. (...) Step Estimated time range Supplier indication Shipping June-Oct 2022 Please indicate earliest
possible delivery date Importation (customs are done by the UN system in Mexico)
1-15 Nov 2022
Local distribution to 9 schools
15-31 Dec 2022
Suppliers should describe the shipping route selected in light of the global CoVID-19 pandemic, and logistical details.
11
ANNEX I
Scope of Supply
Scope of supply
TO BE COMPLETED BY THE BIDDER separately in Appendix 3 and 4 of tender documents
UNIDO REQUIREMENTS
Item Name and required parameters Quantity Complia
nce Remark
s**)
yes/no
I Equipment, parts, supplies I.1 Kit_1
1 Flushing Machine CPS Model AFM100 or Equivalent with 2 gallons of flushing agent 279
2 Air Compressor with hose an connections 279 3 Flushing Kit For A/C 279
4 Nitrogen Blowing Equipment with trolley for the cylinder
279
5 Universal connection Kit for A/A systems flushing 279
6 Multi function digital manifold 279
7 Vacuum pump with electrovalve and vacuum gauge 279
8 Refrigerant recovery machine 279 9 Charge Scale with carrying case 279
10 Charging hoses for R-410A 279 11 Recovery Cylinders 558 12 Clamp on meters 279
13 Pinch off piercing pliers 1/4" SAE connection
1116
14 Mechanical manifold gauge with hoses set 279 15 Leak detector 279 16 Tube cutter 279 Total Kit_1 5580
I.2 Kit_2 1 Flushing Kit For A/C 360
2 Nitrogen Blowing Equipment with trolley for the cylinder
360
3 Universal connection Kit for A/A systems flushing
360
4 Multi function digital manifold 360
5 Vacuum pump with electrovalve and vacuum gauge
360
6 Refrigerant recovery machine 360 7 Charge Scale with carrying case 360 8 Charging hoses for R-410A 360 9 Recovery Cylinders 720
10 Clamp on meters 360
11 Pinch off piercing pliers 1/4" SAE connection
1440
12 Mechanical manifold gauge with hoses set 360 13 Leak detector 360 14 Tube cutter 360
12
Total Kit_2 6,480
Sub-total: 12,060
II Molecular Transformator, please indicate if available 54
III
Warranty (Standard manufacturer's warranty minimum 12 months from the date of acceptance)
IV
Spare parts and consumables (for one year of operation for all listed items, from the date of acceptance by the Beneficiary)
V
Transportation (DAP Mexico to each of the schools) including insurance, packing and unloading
Total price:
13
Language:English
Score: 1116375.1
-
https://www.unido.org/sites/de...tions%20dated%20May%202022.pdf
Data Source: un
Air Quality Assessment
SWITCHING FUEL AND REPLACING BOILERS INCENTIVES TOWARDS CLEAN ENERGY USE BY HOUSEHOLDS
© BMK, Armin Pecher
| SWITCHING FUEL AND REPLACING BOILERS
SUPPORT FOR FUEL SWITCH AND NEW BOILERS
2
ASSURES MULTIPLE POLICY GAINS
Reduces air pollution in residential areas
Mitigates climate change through greenhouse gas emission reductions
Facilitates clean energy use esp. for less wealthy citizens
POLICY MOTIVATION MAY VARY ACCORDING TO SITUATION
Current focus on fuel replacement for climate policy in Austria
Current focus on air quality and social justice in Sofia, Skopje and Sarajevo
© SOLID
| SWITCHING FUEL AND REPLACING BOILERS
EXCHANGE YOUR OLD OIL BOILER AND BE SUPPORTED
3
Funding 2021 for thermal building renovation and boiler replacement “Get out of oil and gas"
On February 9, 2021, the Austrian climate protection ministry's new promotion campaign for thermal building renovation (“renovation check”) and boiler replacement (“get out of oil and gas”) for climate- friendly alternatives. (...) Source: https://www.bmk.gv.at/themen/klima_umwelt/klimaschutz/ufi/sanierung_kesselaustausch.html
https://www.bmk.gv.at/themen/klima_umwelt/klimaschutz/ufi/sanierung_kesselaustausch.html
| SWITCHING FUEL AND REPLACING BOILERS
“OUT OF OIL AND GAS” PROGRAMME 2021 – DETAILS
4
Compared to the previous year, some funding criteria have been simplified and the funding offer made more attractive and uncomplicated:
The period between registration and application will be extended from 5 to 6 months (for "get out of oil and gas").
The maximum subsidy rate will be increased to 35 percent (for “get out of oil and gas”).
District heating connection fees can now also be subsidized.
During the comprehensive renovation, the technical criteria will be adapted to the standard of OIB-RL 6 or klima:aktiv 2020.
If renewable raw materials are used as insulation material, a surcharge of 50 percent can be granted on the respective maximum subsidy flat rate (renovation check in a one or two-family house).
Individual component renovation is funded again (renovation check in one or two-family house):
Submission of an overall renovation concept / energy certificate or energy advice is a requirement for funding.
maximum lump sum funding of 2,000 euros.
| SWITCHING FUEL AND REPLACING BOILERS
EU LIFE INTEGRATED PROJECT IN BULGARIA
5
https://lifeipcleanair.eu/en/index.html
Municipality Sofia (Lead) together with other main Bulgarian cities
Motivated by high exceedances of EU Particulate Matter limit values in Bulgarian cities and an air quality integrated LIFE project in southern Poland
Includes new heating devices and additional air quality monitoring
November 2020 – start of changing heating devices eg in Ruse (overall 1468 households until 2024) and Veliko Tarnovo (overall 548 households until 2024)
The new heating devices may be one of the following types: pellet fireplace, pellet stove with water jacket, pellet boiler with water jacket, gas boiler, gas convector, steel panel radiators.
The dismantling of the old heating equipment using wood and coal, its removal from the home and transportation for recycling, are also provided to the households free of charge
In spite of generous conditions, some administrative challenges to promote swift uptake by housholds – comparable experience as in Austria (access to programmes must be as easy as possible, esp. for socially less favoured households)
https://lifeipcleanair.eu/en/index.html
| SWITCHING FUEL AND REPLACING BOILERS
NORTH MACEDONIA - SKOPJE
6
…. the most recent activity, promoted by the Minister of Environmental Protection of North Macedonia at the recent regional conference organized by the RES Foundation in December 2020, is an initiative from Skopje municipality to subsidize individual households willingly to replace their wood stoves or boilers that use heating oil with new inverter air conditioners.
Each household is entitled to as much as EUR 1,000 within the scheme for improving air quality
https://balkangreenenergynews.com/skopje-supports-its-households-to-reduce-air- pollution/
https://balkangreenenergynews.com/skopje-supports-its-households-to-reduce-air-pollution/
| SWITCHING FUEL AND REPLACING BOILERS
BOSNIA & HERCEGOVINA - SARAJEVO
7
Sarajevo Canton's Strategy for Restricting the Use of Coal and Other Solid Fuels in Sarajevo Canton for 2021-2031, is the first concrete decarbonization plan in Bosnia and Herzegovina. (...) This is an important step to improve air quality. UNDP is also working with the Cantonal government on a subsidy scheme for the replacement of coal furnaces in households with more efficient heating systems.
https://balkangreenenergynews.com/sarajevo-canton-to-ban-coal-use-in-2021- amid-extreme-air-pollution/
https://balkangreenenergynews.com/sarajevo-canton-to-ban-coal-use-in-2021-amid-extreme-air-pollution/
| SWITCHING FUEL AND REPLACING BOILERS
CONTACT & INFORMATION
Gilbert Ahamer
gilbert.ahamer@umweltbundesamt.at
Johannes Mayer
johannes.mayer@umweltbundesamt.at
8
Umweltbundesamt www.umweltbundesamt.at
Towards clean, renewable and efficient energy use UNDA project webinar 23 February 2021
mailto:gilbert.ahamer@umweltbundesamt.at
mailto:gilbert.ahamer@umweltbundesamt.at
https://www.springer.com/de/book/9783319517025
Switching fuel and repLacing boilerS
Support for fuel switch and new boilers
Exchange your old Oil boiler and be supported
“out of oil and gas” programme 2021 – details
Eu life integrated project in bulgaria
North Macedonia - SKOPJE
Bosnia & Hercegovina - SARAJEVO
Contact & Information
Language:English
Score: 1112229.5
-
https://unece.org/sites/defaul..._and%20stove%20replacement.pdf
Data Source: un
ITU Normal.dot
Hotel information and Reservation form
Marriott Grand Hotel (venue for Cybersecurity Symposium II)
125009, Russia, Moscow, 26/1 Tverskaya Street
Contact person: Matushkina Olga e-mail: omatush@marriott-moscow.ru
Website: Marriott Grand Hotel
Category: Five stars
Description: There are 388 apartments with air conditioner, cable TV, telephone, access to the Internet, individual safe and mini bar. (...) Holiday Inn Vinogradovo Hotel (venue for SG17 meeting)
Russia, Moscow, Dmitrovskoe Shosse, 171
Contact person: Nagach Nickolay e-mail: fom@himv.ru
Website: Holiday Inn Vinogradovo
Category: Four stars
Description: There are 154 apartments with air-conditioning, color TV with satellite and video channels, radio, telephone, mini-bar, hair-dryer, safe, 24-hour room service.
Language:English
Score: 1107462.3
-
https://www.itu.int/ITU-T/work...ersecurityII/extract-hotel.doc
Data Source: un
Ozone Depleting Substances disposal
www.unido.org
The Montreal Protocol
and its
impact on Climate Change
www.unido.org
The climate benefits of the accelerated phase-out of HCFCs
www.unido.org
GWP comparative analysis for HCFCs alternatives in the room air conditioner sector
0%
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
G W
P e
m is
si on
s (C
O 2
eq y
r- 1 )
Propane CO2 R410a Business As Usual
■ GWP for refrigerant emission ■ GWP for energy consumption ■ Total
www.unido.org
Challenges ahead Develop environmental friendly and sustainable technologies
Cost and market constrains
Promote and implement environmental friendly Policy
Opportunities Replace old technologies and equipment with mew ones
Select environmental friendly and sustainable technologies
Promote environmental friendly development Strategy
Promote and enforce environmental friendly Policy
www.unido.org
We offer our assistance
in meeting the
challenges
Thank you!