Results 1 - 10 of 17,842 for breathing apparatus. Search took 1.03 seconds.  
Sort by date/Sort by relevance
There are also types of breathing apparatus which give an independent supply of breathable air, e.g. fresh-air hose, compressed airline and self-contained breathing apparatus. (...) Where there is a shortage of oxygen or any danger of losing consciousness due to exposure to high levels of harmful fumes, only use breathing apparatus – never use a filtering cartridge. Breathing apparatus will need to be used in a confined space or if there is a chance of an oxygen deficiency in the work area.
Language:English
Score: 1835077.5 - https://www.ilo.org/global/top...e-equipment/lang--en/index.htm
Data Source: un
MARGINAL 212/1112 OR 201A/2201A [RID/ADR] : BOTTLES FOR BREATHING APPARATUS / TRANSMITTED BY THE EUROPEAN COMMISSION
Bottles specially designed for breathing apparatus are explicitly included in the scope of Directive 97/23/EC concerning pressure equipment (see article 3, paragraph 1.1 (a)). 2. (...) However, if this initial option was not accepted, a second possible solution would consist in including bottles for breathing apparatus in marginal 201a/2201a for small quantities, as has been done for extinguishers (...) Of these two possible solutions the Commission prefers the first for the following reason: this solution would mean that the requirements of RID and the Annexes to ADR concerning periodic inspections would continue to be applicable to bottles for breathing apparatus. Proposal First option Marginal 212/2212 Paragraph (1) Add the following subparagraph at the end: “- for bottles specially designed for breathing apparatus: Annex I to Directive 97/23/EC(8).”
Language:English
Score: 1717228 - daccess-ods.un.org/acce...RANS/WP.15/AC.1/1999/19&Lang=E
Data Source: ods
GE.10-26448 Econo
Sweden considers that breathing apparatus, in meaning of special provision 655, is intended to be used for providing breathable air in a harmful or lethal atmosphere. The expression "breathing apparatus" should therefore not be applicable for breathing equipment used for medical purposes. 4. (...) In special provision 655, add a reference to footnote 4 after "breathing apparatus". The text of the footnote shall read as follows: "A self contained system for providing of breathable air in an immediate danger to life and health atmosphere.".
Language:English
Score: 1700366 - daccess-ods.un.org/acce...TRANS/WP.15/AC.1/2011/7&Lang=E
Data Source: ods
GE.13-22138 (E)
Standard EN 400:1993 deals with self-contained respiratory devices, regenerating devices, self-contained closed-circuit, compressed oxygen breathing apparatus – requirements, testing, and marking. (...) The EN 400:1993 and EN 401:1993 standards have since been replaced by EN 13794:2002 on respiratory protective devices, self-contained closed-circuit breathing apparatus for escape – requirements, testing and marking. (...) The EN 1146:1997 standard on respiratory protective devices, self-contained open- circuit compressed-air breathing apparatus incorporating a hood – requirements, testing, marking, has since been replaced by EN 1146:2005 on self-contained open-circuit compressed air breathing apparatus incorporating a hood for escape – requirements, testing, marking.
Language:English
Score: 1683805.5 - daccess-ods.un.org/acce...RANS/WP.15/AC.2/2013/16&Lang=E
Data Source: ods
Trade in respirators also grew rapidly, by 57 per cent, although the value of this 5 Critical medical products include: disinfectants/ sterilization products; face masks; gloves; hand soap and hand sanitizer; patient monitors and pulse oximeters; protective spectacles and visors; sterilizers; syringes; thermometers; ultrasonic scanning apparatus; ventilators, oxygen masks; X-ray equipment; and other devices such as computer tomography apparatus. 2.4 2.4 2.3 3.0 0.1 15.8 5.5 9.6 11.6 50.3 0.0 10.0 20.0 30.0 40.0 50.0 60.0 All Medical equipment Medical Supplies Medicine Personal Protective Products Ye ar o n y ea r p er ce n ta ge c h an ge 1st half of 2019 compared to 2018 1st half of 2020 compared to 2019 Medical equipment, 14% Medical Supplies, 17% Medicine, 55% Face Masks, 7.8% Hand Sanitizers, 3.6% Hand Soaps, 2.2% Other Protective Covers, 0.3% Personal Protective Products, 14% 2019 - US$ 983 billion Medical equipment, 13% Medical Supplies, 16% Medicine, 53% Face Masks, 12.6% Hand Sanitizers, 3.0% Hand Soaps, 2.1% Other Protective Covers, 0.3% Personal Protective Products, 18% 2020 - US$ 1,139 billion 4 trade amounted to only US$ 13 billion, equivalent to just over 1 per cent of trade in all medical goods. (...) X 300220 Vaccines for human medicine X 300310 Medicaments containing penicillins … not for retail sale X 300320 Medicaments containing antibiotics, … not for retail sale X 300331 Medicaments containing insulin, … not for retail sale X 300339 Medicaments containing hormones … not for retail sale X 300341 Medicaments containing ephedrine … not for retail sale X 300342 Medicaments containing pseudoephedrine "INN" or its salts, … not for retail sale X 300343 Medicaments containing norephedrine or its salts, … not for retail sale X 300349 Medicaments containing alkaloids or derivatives thereof, … not for retail sale X 300360 Medicaments containing any of the following antimalarial active principles: … not put up for retail sale X 300390 Medicaments consisting of two or more constituents mixed together for therapeutic or prophylactic uses, not for retail sale X 300410 Medicaments containing penicillins or derivatives thereof … for retail sale X 300420 Medicaments containing antibiotics, ... for retail sale X 300431 Medicaments containing insulin but not antibiotics, ... for retail sale X 300432 Medicaments containing corticosteroid hormones, ... for retail sale X 300439 Medicaments containing hormones or steroids ... for retail sale X 300441 Medicaments containing ephedrine or its salts, ... for retail sale X 300442 Medicaments containing pseudoephedrine "INN" or its salts, ... for retail sale X 300443 Medicaments containing norephedrine or its salts, ... for retail sale X 300449 Medicaments containing alkaloids or derivatives thereof... for retail sale X 300450 Medicaments containing provitamins, vitamins,... for retail sale X 300460 Medicaments containing any of the following antimalarial active principles ... for retail sale X 300490 Medicaments consisting of mixed or unmixed products ... for retail sale X X Medical Supplies HS 2017 Short product description ITA-E Pharma WCO 220710 Undenatured ethyl alcohol, of actual alcoholic strength of >= 80% X 284700 Hydrogen peroxide, whether or not solidified with urea X 300120 Extracts of glands or other organs or of their secretions, for organo-therapeutic uses X 300190 Dried glands and other organs for organo-therapeutic uses; heparin and its salts, … X 300212 Antisera and other blood fractions X 300290 Human blood; animal blood ...; toxins, cultures of micro-organisms and similar products X 300510 Adhesive dressings and other articles ... put up for retail sale for medical, surgical, dental or veterinary purposes X 300590 Wadding, gauze, bandages and the like put up for retail sale for medical, surgical, dental or veterinary purposes X X 300610 Sterile surgical catgut, similar sterile suture materials,… X 10 Columns "ITA-Exp", "Parma", and "WCO" indicate if the HS codes are also part of the ITA Expansion, Pharmaceutical Agreement, or WCO HS Classification reference for Covid-19 medical supplies 10 HS 2017 Short product description ITA-E Pharma WCO 300620 Reagents for determining blood groups or blood factors X 300630 Opacifying preparations for x-ray examinations; diagnostic reagents for administration to patients X 300650 First-aid boxes and kits X 300670 Gel preparations designed to be used in human or veterinary medicine … X 340212 Cationic organic surface-active agents 340213 Non-ionic organic surface-active agents 350400 Peptones and their derivatives; other protein substances and their derivatives, n.e.s.; … 350790 Enzymes and prepared enzymes, n.e.s. 370110 Photographic plates and film in the flat, sensitised, unexposed, for X-ray 370210 Photographic film in rolls, unexposed, for X-ray 380894 Disinfectants, put up in forms or packings for retail sale X 382100 Prepared culture media for the development or maintenance of micro-organisms 382200 Diagnostic or laboratory reagents on a backing, prepared diagnostic or laboratory reagents and certified reference materials X 392620 Articles of apparel and clothing accessories produced by the stitching or sticking together of plastic sheeting X 401490 Hygienic or pharmaceutical articles 401511 Surgical gloves, of vulcanised rubber X 401519 Gloves, mittens and mitts, of vulcanised rubber X 701710 Laboratory, hygienic or pharmaceutical glassware, of fused quartz or other fused silica 701720 Laboratory, hygienic or pharmaceutical glassware having a linear coefficient of expansion <= 5 x 10 -6 per kelvin within a temperature range of 0°C to 300°C 701790 Laboratory, hygienic or pharmaceutical glassware n.e.s 901831 Syringes, with or without needles, used in medical, surgical, dental or veterinary sciences X 901832 Tubular metal needles and needles for sutures, used in medical, surgical, dental or veterinary sciences X 901839 Needles, catheters, cannulae and the like, used in medical, surgical, dental or veterinary sciences X Medical Equipment HS 2017 Short product description ITA-E Pharma WCO 841920 Medical, surgical or laboratory sterilizers X 901050 Apparatus and equipment ....; negatoscopes X 901110 Stereoscopic optical microscopes X 901180 Optical microscopes X 901811 Electro-cardiographs X 901812 Ultrasonic scanning apparatus X 901813 Magnetic resonance imaging apparatus X 901814 Scintigraphic apparatus 901819 Other electro-diagnostic apparatus X X 901820 Ultraviolet or infra-red ray apparatus used in medical, surgical, dental or veterinary sciences X 901890 Instruments and appliances used in medical, surgical or veterinary sciences, n.e.s. X X 901920 Ozone therapy, oxygen therapy, aerosol therapy, artificial respiration or other therapeutic respiration apparatus X 902150 Pacemakers for stimulating heart muscles X 902212 Computer tomography apparatus X X 902214 Apparatus based on the use of X-rays, for medical, surgical or veterinary uses X 902219 Apparatus based on the use of X-rays X 902221 Apparatus based on the use of alpha, beta or gamma radiations, for medical, surgical, dental or veterinary uses X 902229 Apparatus based on the use of alpha, beta or gamma radiations, n.e.s X 902230 X-ray tubes X 11 HS 2017 Short product description ITA-E Pharma WCO 902290 X-ray generators, high tension generators, control panels and desks, screens, … X 902511 Thermometers, liquid-filled, for direct reading, not combined with other instruments X 902519 Thermometers and pyrometers, not combined with other instruments X X 902780 Instruments and apparatus for physical or chemical analysis, or for measuring or checking viscosity … X X 903020 Oscilloscopes and oscillographs X 940290 Operating tables, examination tables, and other medical, dental, surgical or veterinary furniture Personal Protective Products HS 2017 Short product description ITA-E Pharma WCO 340111 Hand soap 340130 Hand soap 340220 Other cleaning products 382499 Hand sanitizer 392690 Face masks 630790 Face masks X 900490 Protective spectacles and visors X 902000 Face masks X 12 ANNEX 2: Table 5: World exports and imports of face masks by HS subheading HS Subheading and standard description Value in US$ million 2018 2019 2020 S1 S2 S1 S2 S1 EXPORTS 3926.90 – Articles of plastics and articles of other materials of heading 3901 to 3914, n.e.s.* 31,475 30,969 31,523 31,997 29,142 6307.90 – Made-up articles of textile materials, incl. dress patterns, n.e.s. 5,474 5,671 5,528 5,992 39,687 9020.00 – Breathing appliances and gas masks 958 957 929 912 1,194 IMPORTS 3926.90 – Articles of plastics and articles of other materials of heading 3901 to 3914, n.e.s. 31,217 30,644 31,251 31,180 28,636 6307.90 – Made-up articles of textile materials, incl. dress patterns, n.e.s. 6,038 6,466 6,499 6,830 43,453 9020.00 – Breathing appliances and gas masks 854 846 855 825 1,427 HS Subheading and standard description Year-on-year semestral growth rate (%) S1 2019/18 S2 2019/18 S1 2020/19 EXPORTS 3926.90 – Articles of plastics and articles of other materials of heading 3901 to 3914, n.e.s. 0.2 3.3 -7.6 6307.90 – Made-up articles of textile materials, incl. dress patterns, n.e.s. 1.0 5.7 617.9 9020.00 – Breathing appliances and gas masks -3.0 -4.7 28.5 IMPORTS 3926.90 – Articles of plastics and articles of other materials of heading 3901 to 3914, n.e.s. 0.1 1.7 -8.4 6307.90 – Made-up articles of textile materials, incl. dress patterns, n.e.s. 7.6 5.6 568.6 9020.00 – Breathing appliances and gas masks 0.1 -2.5 66.9 HS Subheading and standard description Growth rate over previous half year (%) S2 18/ S1 18 S1 19/ S2 18 S2 19/ S1 19 S1 20/ S2 19 EXPORTS 3926.90 – Articles of plastics and articles of other materials of heading 3901 to 3914, n.e.s. -1.6 1.8 1.5 -8.9 6307.90 – Made-up articles of textile materials, incl. dress patterns, n.e.s. 3.6 -2.5 8.4 562.3 9020.00 – Breathing appliances and gas masks -0.1 -2.9 -1.8 30.9 IMPORTS 3926.90 – Articles of plastics and articles of other materials of heading 3901 to 3914, n.e.s. -1.8 2.0 -0.2 -8.2 6307.90 – Made-up articles of textile materials, incl. dress patterns, n.e.s. 7.1 0.5 5.1 536.2 9020.00 – Breathing appliances and gas masks -0.9 1.1 -3.5 73.0 * n.e.s. is “not elsewhere specified”. __________
Language:English
Score: 1668752 - https://www.wto.org/english/tr...9_e/medical_goods_update_e.pdf
Data Source: un
PROPOSAL OF AMENDMENT TO CHAPTER 3.2 [RID/ADR] : REMOVE ENTRIES OF PORTABLE TANK SPECIAL PROVISION TP13 FROM COLUMN 11 OF TABLE A / TRANSMITTED BY THE EUROPEAN CHEMICAL INDUSTRY COUNCIL (CEFIC)
Justification The requirement for a self contained breathing apparatus may well be appropriate for marine transport but should not be recommended for drivers of transport units carrying dangerous goods by road or by rail. Rather than loosing time and endangering his life whilst putting on the breathing apparatus, a driver should make use of an escape mask and should leave the danger area as soon as possible in case of emergencies involving such dangerous goods. As far as road and rail transport is concerned, a self contained breathing apparatus is reserved for trained fire fighters who can make an approach from outside the scene of the accident.
Language:English
Score: 1662371.7 - daccess-ods.un.org/acce...RANS/WP.15/AC.1/2002/10&Lang=E
Data Source: ods
HARMONISATION DE LA TERMINOLOGIE UTILISÉE DANS L’ADN 2021 POUR « HABITS DE PROTECTION », « ÉQUIPEMENT DE PROTECTION » ET « ÉQUIPEMENT DE PROTECTION INDIVIDUELLE »
(Where service spaces are located in the cargo area under deck, they shall be arranged so as to be easily accessible and to permit persons wearing personal protective equipment clothing and breathing apparatus to safely operate the service equipment contained therein. (...) (Where service spaces are located in the cargo area under deck, they shall be arranged so as to be easily accessible and to permit persons wearing personal protective equipment clothing and breathing apparatus to safely operate the service equipment contained therein. (...) Column (18): Determination of whether personal protective equipment, escape devices, portable gas detectors, portable toximeters or ambient-air-dependent breathing apparatus is required […] 3.2.4.3 Zuordnungskriterien für die Stoffe […] J.
Language:English
Score: 1652645 - https://daccess-ods.un.org/acc...TRANS/WP.15/AC.2/2022/3&Lang=E
Data Source: ods
In the "sunny layer," divers equipped with breathing apparatus can stay down for an average of twenty minutes and enjoy considerable security and freedom of movement. (...) Later, Pierre Drach pioneered scientific research with freediving apparatus. Under his leadership, the divers of the Calypso methodically gathered harvests in the Red Sea in 1951. (...) Self-contained diving apparatus has enabled us to enter the twilight layer: breathing air, Italian divers have managed to reach a depth of 120 metres for a few seconds.
Language:English
Score: 1646250 - https://en.unesco.org/courier/...ugust-1960/aqualung-bathyscaph
Data Source: un
PROPOSALS OF AMENDMENTS TO RID/ADR/ADN : BREATHING APPLIANCES DESIGNED AND CONSTRUCTED ACCORDING TO DIRECTIVE 97/23/EC (PED) / TRANSMITTED BY THE GOVERNMENT OF SWEDEN
It is therefore impossible to transport a PED breathing appliance according to the RID/ADR without using an exemption. (...) But Sweden is aware of that this is not the case with all breathing appliances that have been put on the European market. (...) “1.6.2.X Bottles for breathing apparatus and their closures designed, constructed and built before 1 January 2009 according to the Directive 97/23/EC of the European Parliament and of the Council of 29 May 1997 on the approximation of the laws of the Member States concerning pressure equipment (PED) and used for breathing apparatus, but however are not approved according to the requirements of Chapter 6.2, may continue to be carried after that date provided they are periodically inspected according to the applicable requirements of packing instruction P200.”
Language:English
Score: 1608376.1 - daccess-ods.un.org/acce...RANS/WP.15/AC.1/2007/45&Lang=E
Data Source: ods
PROPOSALS FOR AMENDMENTS TO RID/ADR/ADN : CYLINDERS FOR BREATHING APPLIANCES / TRANSMITTED BY THE GOVERNMENT OF FRANCE
It was decided to add the following new special provision 655: “655 Cylinders and their closures designed, constructed and approved in accordance with Directive 97/23/EC of the European Parliament and of the Council of 29 May 1997 on the approximation of the laws of the Member States concerning pressure equipment (PED) and used for breathing apparatus may be carried without additional approval in accordance with Chapter 6.2, provided they are periodically inspected in accordance with the applicable requirements of packing instruction P200 in 4.1.4.1. (...) Some countries apply to breathing appliance cylinders inspection measures that differ from those used for the periodic inspection of portable cylinders containing air which are subject to RID/ADR. Such measures are often more restrictive, since: − The breathing apparatus is “transported” on a human back, and this calls for extra caution; and − The sorts of deterioration to which the equipment is subject to depend on the use to which it is put (the corrosive environment of diving, and thermal constraints during exposure to fire in firefighting operations ...). 4.
Language:English
Score: 1601431.7 - daccess-ods.un.org/acce...RANS/WP.15/AC.1/2008/19&Lang=E
Data Source: ods